1.
Place arm on drape provided in dressing change
kit.
2.
Open StatLock and Biopatch packages into the
dressing change kit box.
3.
With gloves on, remove the occlusive dressing by
pulling up the edges and then pulling the dressing toward the midline.
4.
With gloves on, pull up edges of StatLock. Unclip the locks on the StatLock. With one hand, lift the PICC line up, while
pulling the StatLock off the skin with the other hand.
5.
With gloves on, remove Biopatch from around the
PICC line at the insertion point.
6.
With gloves on, use alcohol (if appropriate) to
clean any remaining adhesive from the area.
7.
Put on sterile gloves provided with dressing
change kit.
8.
Disinfect the area around the PICC line (either
with chlorhexidine or betadine.) Allow
to dry. Do not touch the area while
drying.
9.
Connect wings of PICC line to StatLock and apply
StatLock to the skin. Apply Skinprep to
the the skin prior to pressing the StatLock to the skin (if appropriate.)
10.
Apply Biopatch to the PICC line near the
insertion site.
11.
Apply occlusive dressing. (I use IV3000.)
12.
Use adhesive strips from the StatLock package to
secure the PICC line where it exits from the occlusive dressing.
PICC Line Blood Draw Procedure:
1.
Flush line with 10ml sterile saline.
2.
With the same syringe still attached, gently
draw back to pull 5ml of blood into the syringe.
3.
Disconnect syringe containing blood.
4.
Attach needleholder/Vacutainer. DO NOT STERILIZE PICC LINE CLAVE IMMEDIATELY
BEFORE THIS STEP.
5.
Insert appropriate tube into needle holder and
collect appropriate amount of blood.
6.
Remove tube.
7.
Disconnect needleholder/Vacutainer.
8.
Flush line with 10ml sterile saline.
9.
Flush line with 10ml sterile saline again.
10.
Lock line with 5ml heparin.
No comments: